FixVault

Component Inspection

  1. CHECK EXHAUST VALVE TIMING CONTROL MAGNET RETARDER
    1. Turn ignition switch OFF.
    2. Disconnect exhaust valve timing control magnet retarder harness connector.
    3. Check resistance between exhaust valve timing control magnet retarder terminals as follows.
      Terminals Resistance
      1 and 2 9.0 - 11.0 Ω [at 20°C (68°F)]

      Is the inspection result normal? 

      YES: INSPECTION END

      NO: GO TO 2.

  2. REPLACE EXHAUST VALVE TIMING CONTROL MAGNET RETARDER
    1. Replace malfunctioning exhaust valve timing control magnet retarder. Refer to "REMOVAL AND INSTALLATION ".
    2. Perform "EXHAUST VALVE TIMING CONTROL LEARNING: SPECIAL REPAIR REQUIREMENT ".

      INSPECTION END