FixVault

PASSENGER SIDE: Component Function Check

  1. CHECK FUNCTION 
    1. Select "MIR/SEN RH U-D", "MIR/SEN RH R-L" in "Data monitor" with CONSULT.
    2. Check the mirror sensor (passenger side) signal under the following conditions.
      Monitor item Condition Value
      MIR/SEN RH U-D Door mirror (passenger side) Change between
      3.4 [V] (close to peak)
      0.6 [V] (close to valley)
      MIR/SEN RH R-L Change between
      3.4 [V] (close to left edge)
      0.6 [V] (close to right edge)

      Is the indication normal? 

      YES: INSPECTION END

      NO: Perform diagnosis procedure. Refer to "PASSENGER SIDE: DIAGNOSIS PROCEDURE ".