FixVault

Detailed Flow

  1. OBTAIN INFORMATION ABOUT SYMPTOM 

    Interview the customer to obtain as much information as possible about the conditions and environment under which the malfunction occurred.

    : GO TO 2.

  2. CHECK SYMPTOM 
    • Check the symptom based on the information obtained from the customer.
    • Check that any other malfunctions are present.

    : GO TO 3.

  3. CHECK ON BOARD DIAGNOSIS OPERATION 

    Check that the on board diagnosis function operates. Refer to "ON BOARD DIAGNOSIS FUNCTION ".

    Does the on board diagnosis function operate normally? 

    YES: GO TO 4.

    NO: GO TO  6.

  4. CHECK CONSULT SELF-DIAGNOSIS RESULTS 
    1. Connect CONSULT and perform self-diagnosis. Refer to "DTC INDEX ".
    2. When DTC is detected, follow the instructions below:
      • Record DTC and Freeze Frame Data.

      Are self-diagnosis results normal? 

      YES: GO TO 5.

      NO: GO TO  10.

  5. NARROW DOWN THE MALFUNCTIONING PARTS BY SYMPTOM DIAGNOSIS 

    Perform symptom diagnosis and narrow down the malfunctioning parts.

    : GO TO  10.

  6. CHECK METER CONTROL SWITCH SIGNAL CIRCUIT 

    Check meter control switch signal circuit. Refer to "DIAGNOSIS PROCEDURE ".

    Is inspection result OK? 

    YES: GO TO 7.

    NO: GO TO  10.

  7. CHECK METER CONTROL SWITCH 

    Check meter control switch. Refer to "COMPONENT INSPECTION ".

    Is inspection result OK? 

    YES: GO TO 8.

    NO: GO TO  10.

  8. CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUITS 

    Check combination meter power supply and ground circuits. Refer to "COMBINATION METER: DIAGNOSIS PROCEDURE ".

    Is inspection result OK? 

    YES: GO TO 9.

    NO: GO TO  10.

  9. REPLACE COMBINATION METER 

    Replace combination meter.

    : GO TO  11.

  10. REPAIR OR REPLACE MALFUNCTIONING PARTS 

    Repair or replace the malfunctioning parts.

    NOTE: If DTC is displayed, erase DTC after repair or replace malfunctioning parts.

    : GO TO 11.

  11. FINAL CHECK 

    Check that the combination meter operates normally.

    Do they operate normally? 

    YES: INSPECTION END

    NO: GO TO  1.