FixVault

Diagnosis Procedure

  1. CHECK ECM POWER SUPPLY 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the voltage between ECM harness connector terminals as per the following.
      ECM Voltage
      + -
      Connector Terminal Connector Terminal
      F102 93 M107 128 Battery voltage

      Is the inspection result normal? 

      YES: GO TO  3.

      NO: GO TO 2.

  2. DETECT MALFUNCTIONING PART 

    Check the following.

    • Harness connectors E20, F40
    • 15 A fuse (No. 51)
    • IPDM E/R harness connector E5
    • Harness for open or short between ECM and battery

      : Repair or replace harness or connectors.

  3. CHECK INTERMITTENT INCIDENT 

    Refer to "INTERMITTENT INCIDENT ".

    Is the inspection result normal? 

    YES: GO TO 4.

    NO: Repair or replace harness or connectors.

  4. PERFORM DTC CONFIRMATION PROCEDURE 
    1. Turn ignition switch ON.
    2. Erase DTC.
    3. Perform DTC Confirmation Procedure. 

      See "DTC LOGIC ".

      Is the 1st trip DTC P0603 displayed again? 

      YES: GO TO 5.

      NO: INSPECTION END

  5. REPLACE ECM 
    1. Replace ECM.
    2. Go to "WORK PROCEDURE ".

      : INSPECTION END