Component Inspection (VVEL ACTUATOR MOTOR)

  1. CHECK VVEL ACTUATOR MOTOR 
    1. Turn ignition switch OFF.
    2. Disconnect VVEL actuator motor harness connector.
    3. Check resistance between VVEL actuator motor terminals as follows.
      VVEL actuator motor Resistance
      Terminal
      1 and 2 16 Ω or less

      Is the inspection result normal? 

      YES: INSPECTION END

      NO: GO TO 2.

  2. REPLACE VVEL ACTUATOR SUB ASSEMBLY 
    1. Replace VVEL actuator sub assembly.
    2. Go to "SPECIAL REPAIR REQUIREMENT ".