FixVault

Component Function Check

  1. BRAKE WARNING LAMP OPERATION CHECK 1 

    Check that the lamp illuminates for approximately 1 second after the ignition switch is turned ON.

    Is the inspection result normal? 

    YES: GO TO 2.

    NO: Proceed to diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".

  2. BRAKE WARNING LAMP OPERATION CHECK 2 

    Check that the brake warning lamp in the combination meter turns ON/OFF correctly when operating the parking brake lever (M/T) or the parking brake pedal (A/T).

    Is the inspection result normal? 

    YES: INSPECTION END

    NO: Check the parking brake switch. Refer to "COMPONENT INSPECTION ".