Component Function Check
- CHECK FUNCTION
- Select "RECLN SW-FR", "RECLN SW-RR" in "DATA MONITOR" mode with CONSULT.
- Check reclining switch signal under the following conditions.
Monitor item Condition Status RECLN SW-FR Reclining switch (forward) Operate ON Release OFF RECLN SW-RR Reclining switch (backward) Operate ON Release OFF Is the inspection result normal?
YES: Inspection End.
NO: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".