Component Function Check
- CHECK FUNCTION
- Select "SLIDE PULSE" in "DATA MONITOR" mode with CONSULT.
- Check sliding sensor switch signal under the following conditions.
Monitor item Condition Value SLIDE PULSE Seat sliding Operate (forward) Change (decrease) Operate (backward) Change (increase) Release No change Is the inspection result normal?
YES: Inspection End.
NO: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".