FixVault

Detailed Flow

  1. COLLECT INFORMATION FROM THE CUSTOMER 

    Get detailed information from the customer about the symptom (the condition and the environment when the incident/malfunction occurred) using the diagnostic worksheet. Refer to "DIAGNOSTIC WORK SHEET ".

    GO TO 2.

  2. PERFORM SELF-DIAGNOSTIC RESULT 

    Perform self-diagnostic result. Refer to "CONSULT FUNCTION ".

    Are any DTCs displayed? 

    YES: Refer to "DTC INDEX ".

    NO: GO TO 3.

  3. CHECK SYMPTOM OPERATING CONDITION 

    Check that the symptom is a normal operating condition. Refer to "DESCRIPTION ".

    Is the symptom a normal operating condition? 

    YES: Inspection End.

    NO: GO TO 4.

  4. CHECK WARNING AND INDICATOR LAMPS OPERATION 

    Check ABS and brake warning lamps, VDC OFF and SLIP indicator lamps operation. Refer to "SYSTEM DESCRIPTION ".

    Is ON/OFF timing normal? 

    YES: GO TO 5.

    NO: Perform warning lamp diagnosis. Refer to "COMPONENT FUNCTION CHECK " (ABS warning lamp), "COMPONENT FUNCTION CHECK " (brake warning lamp), "COMPONENT FUNCTION CHECK " (VDC OFF indicator lamp) or "COMPONENT FUNCTION CHECK " (SLIP indicator lamp).

  5. PERFORM DIAGNOSIS APPLICABLE TO THE SYMPTOM 

    Perform diagnosis applicable to the symptom. Refer to "SYMPTOM TABLE ".

    GO TO 6.

  6. FINAL CHECK 

    Perform self-diagnostic result again, and check that the malfunction is repaired. After checking, erase the self-diagnosis memory. Refer to "CONSULT FUNCTION ".

    Inspection End.