FixVault

DTC Index

CONSULT display Fail-safe TIME(1) Refer to
No DTC is detected. Further testing may be required. - - - -
U1000: CAN COMM CIRCUIT x CRNT 1 - 39 U1000 CAN COMM CIRCUIT 
U1010: CONTROL UNIT (CAN) x CRNT 1 - 39 U1010 CONTROL UNIT (CAN) 
B2098: IGN RELAY ON x CRNT 1 - 39 B2098 IGNITION RELAY ON STUCK 
B2099: IGN RELAY OFF - CRNT 1 - 39 B2099 IGNITION RELAY OFF STUCK 
B210B: INHIBIT relay ON stuck failure - CRNT 1 - 39  
B210C: INHIBIT relay OFF stuck failure - CRNT 1 - 39  
B210D: STARTER relay ON stuck failure - CRNT 1 - 39  
B210E: STARTER relay OFF stuck failure - CRNT 1 - 39  
B210F: Interlock/NP switch ON stuck failure - CRNT 1 - 39  
B2110: Interlock/NP switch OFF stuck failure - CRNT 1 - 39  
NOTE:
(1) The details of TIME display are as follows.
  • CRNT: The malfunctions that are detected now
  • 1 - 39: The number is indicated when it is normal at present and a malfunction was detected in the past. It increases like 0 → 1 → 2... 38 → 39 after returning to the normal condition whenever IGN OFF → ON. It is fixed to 39 until the self-diagnosis results are erased if it is over 39. It returns to 0 when a malfunction is detected again in the process.