FixVault

Ignition Battery Saver System

When all the following conditions are met for 30 minutes, the battery saver system will cut off the power supply (ignition switch position ACC/ON → OFF) to prevent battery discharge.

NOTE: For one minute after thirty minutes have passed or three minutes after twenty-seven minutes are passed, the following display is indicated on information display in combination meter and sounds buzzer in combination meter.
Combination meter Time
Information display Buzzer
Power turned off to save the battery Pipi-Pipi (two seconds) For one minute after thirty minutes have passed
three minutes after twenty-seven minutes are passed

Reset Condition of Ignition Battery Saver System

If any of the following conditions are met the battery saver system is released.

NOTE: The ignition battery saver system can be temporarily disabled, without using CONSULT, to prevent it from functioning when performing trouble diagnosis. Refer to "WORK PROCEDURE ".