FixVault

Component Function Check

  1. CHECK FUNCTION

    1. Turn ignition switch ON.
    2. Select "WALK-IN SW" in the "Data Monitor" mode using CONSULT.
    3. Check the power walk-in switch signal under the following condition.
    Test item Condition Status
    WALK-IN SW Power walk-in switch Pressed ON
    Released OFF

    Is the indication normal?

    YES 

    INSPECTION END

    NO 

    Perform diagnosis procedure. Refer to DIAGNOSIS PROCEDURE .