  1. CHECK FUNCTION

    1. Turn ignition switch ON.
    2. Select "SLIDE PULSE" in "Data monitor" mode with CONSULT.
    3. Check sliding sensor signal under the following conditions.
    Monitor item Condition Valve
    SLIDE PULSE Seat sliding Operate (forward) Change (increase)*1
    Operate (backward) Change (decrease)*1
    Release No change*1

    *1 : The value at the seat position attained when the battery is connected is considered to be 32768.

    Is the indication normal?

    YES 

    INSPECTION END

    NO 

    Perform diagnosis procedure. Refer to DIAGNOSIS PROCEDURE .