FixVault

Component Function Check

  1. CHECK FUNCTION

    1. Select "SLIDE SW-FR", "SLIDE SW-RR" in "Data monitor" mode using CONSULT.
    2. Check sliding switch signal under the following conditions.
    Monitor item Condition Status
    SLIDE SW-FR Sliding switch (forward) Operate ON
    Release OFF
    SLIDE SW-RR Sliding switch (backward) Operate ON
    Release OFF

    Is the indication normal?

    YES 

    INSPECTION END

    NO 

    Perform diagnosis procedure. Refer to DIAGNOSIS PROCEDURE .