FixVault

Component Function Check

  1. CHECK CK SUSP INDICATOR LAMP OPERATION

    G-20 With CONSULT

    1. Turn ignition switch ON.
    2. Select "WARNING LAMP" in "Active Test" in "E-SUS".
    3. While operating test item, check that the CK SUSP indicator lamp activates.
      ON : CK SUSP indicator lamp turns ON
      OFF : CK SUSP indicator lamp turns OFF

    Is the inspection result normal?

    YES 

    INSPECTION END

    NO 

    Refer to DIAGNOSIS PROCEDURE .