FixVault

Diagnosis Procedure

  1. PERFORM INITIALIZATION PROCEDURE

    Initialization procedure is performed and operation is confirmed.

    Refer to WORK PROCEDURE 

    Is the inspection result normal?

    YES 

    INSPECTION END

    NO 

    GO TO STEP 2  .

  2. CHECK DRIVER SIDE DOOR LOCK ASSEMBLY (DOOR KEY CYLINDER SWITCH)

    Check front door lock assembly (driver side) (door key cylinder switch).

    Refer to COMPONENT FUNCTION CHECK .

    Is the inspection result normal?

    YES 

    GO TO STEP 3  .

    NO 

    Repair or replace the malfunctioning parts.

  3. CONFIRM THE OPERATION

    Confirm the operation again.

    Is the result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    GO TO STEP 1  .