FixVault

Data Monitor

WARNING: This page is about a different car, the 2019 Infiniti Q50. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: The following table includes information (items) inapplicable to this vehicle. For information (items) applicable to this vehicle, refer to CONSULT display items.

Monitor Item

Unit

Contents

STARTER SW

On/Off

The ignition switch position "OFF (other than cranking) / ON (cranking)" judged from the ignition switch signal.

SET SW*

On/Off

ON/OFF status judged from the setting switch signal.

MEMORY SW 1*

On/Off

ON/OFF status judged from the seat memory switch 1 signal.

MEMORY SW 2*

On/Off

ON/OFF status judged from the seat memory switch 2 signal.

DETENT SW

On/Off

The selector lever status "OFF (P position) / ON (other than P position or press the selector button with selector lever in P position)" judged from the detention switch signal.

STEERING STATUS

LOCK/UNLOCK

Power supply position "LOCK/UNLOCK (other than lock)" judged by BCM,

SLIDE SW-FR

On/Off

ON/OFF status judged from the sliding switch (forward) signal.

SLIDE SW-RR

On/Off

ON/OFF status judged from the sliding switch (backward) signal.

RECLN SW-FR

On/Off

ON/OFF status judged from the reclining switch (forward) signal.

RECLN SW-RR

On/Off

ON/OFF status judged from the reclining switch (backward) signal.

LIFT FR SW-UP

On/Off

ON/OFF status judged from the lifting switch front (up) signal.

LIFT FR SW-DN

On/Off

ON/OFF status judged from the lifting switch front (down) signal.

LIFT RR SW-UP

On/Off

ON/OFF status judged from the lifting switch rear (up) signal.

LIFT RR SW-DN

On/Off

ON/OFF status judged from the lifting switch rear (down) signal.

TILT SW-UP*

On/Off

ON/OFF status judged from the tilt switch (up) signal.

TILT SW-DOWN*

On/Off

ON/OFF status judged from the tilt switch (down) signal.

TELESCO SW-FR*

On/Off

ON/OFF status judged from the telescoping switch (forward) signal.

TELESCO SW-RR*

On/Off

ON/OFF status judged from the telescoping switch (backward) signal.

MIR CON SW-UP*

On/Off

ON/OFF status judged from the mirror switch (up) signal.

MIR CON SW-DN*

On/Off

ON/OFF status judged from the mirror switch (down) signal.

MIR CON SW-RH*

On/Off

ON/OFF status judged from the door mirror remote control switch (passenger side) signal.

MIR CON SW-LH*

On/Off

ON/OFF status judged from the door mirror remote control switch (driver side) signal.

MIR CHNG SW-R*

On/Off

ON/OFF status judged from the door mirror remote control switch (switching to right) signal.

MIR CHNG SW-L*

On/Off

ON/OFF status judged from the door mirror remote control switch (switching to left) signal.

TILT PULSE*

--

Value (32768) when battery connections are standard. If it moves DOWN, the value increases. If it moves UP, the value decreases.

TELESCO PULSE*

--

Value (32768) when battery connections are standard. If it moves backward, the value increases. If it moves forward, the value decreases.

MIR/SEN RH U-D*

V

Voltage input from door mirror sensor (passenger side) up/down is displayed.

MIR/SEN RH R-L*

V

Voltage input from door mirror sensor (passenger side) left/right is displayed.

MIR/SEN LH U-D*

V

Voltage input from door mirror sensor (driver side) up/down is displayed.

MIR/SEN LH R-L*

V

Voltage input from door mirror sensor (driver side) left/right is displayed.

SLIDE PULSE

--

Value (32768) when battery connections are standard. If it moves backward, the value increases. If it moves forward, the value decreases.

RECLN PULSE*

--

Value (32768) when battery connections are standard. If it moves backward, the value increases. If it moves forward, the value decreases.

LIFT FR PULSE*

--

Value (32768) when battery connections are standard. If it moves DOWN, the value increases. If it moves UP, the value decreases.

LIFT RR PULSE*

--

Value (32768) when battery connections are standard. If it moves DOWN, the value increases. If it moves UP, the value decreases.

VEHICLE SPEED

--

Display the vehicle speed signal received from combination meter by numerical value [km/h].

P RANG SW CAN

On/Off

ON/OFF status judged from the P range switch signal.

R RANGE (CAN)

On/Off

ON/OFF status judged from the R range switch signal.

DOOR SW-FL

Open/Close

OPEN/CLOSE status judged from the door switch (driver side) signal.

DOOR SW-FR

Open/Close

OPEN/CLOSE status judged from the door switch (passenger side) signal.

IGN ON SW

On/Off

ON/OFF status judged from the ignition switch signal.

ACC ON SW

On/Off

ON/OFF status judged from the ACC switch signal.

KYLS DR UNLK

On/Off

ON/OFF status judged from the driver side door unlock actuator output switch signal.

KEYLESS ID

ID1/ID2/ID3/ID4

Key ID status judged from the key ID signal.

VHCL SPEED (ABS)

RCV/NORCV

Received/Not received status judged from vehicle speed signal.

HANDLE

LHD/RHD

RHD/LHD status judged from handle position signal.

TRANSMISSION

AT/MT

AT/MT status judged from transmission.

INITIAL STATE*

DONE/YET

Displays the default status of the log-in function.

USER1 REGIST*

DONE/YET

Displays the USER1 registration or non-registration status of the log-in function.

USER2 REGIST*

DONE/YET

Displays the USER2 registration or non-registration status of the log-in function.

USER3 REGIST*

DONE/YET

Displays the USER3 registration or non-registration status of the log-in function.

USER4 REGIST*

DONE/YET

Displays the USER4 registration or non-registration status of the log-in function.

LOGIN USER*

User1/User2/User3/User4

Displays the current log-in user with the log-in function.

USER1 SW*

On/Off

ON/OFF status judged from user1 change switch signal.

USER2 SW*

On/Off

ON/OFF status judged from user2 change switch signal.

USER3 SW*

On/Off

ON/OFF status judged from user3 change switch signal.

USER4 SW*

On/Off

ON/OFF status judged from user4 change switch signal.

LOGIN USER CHANGE*

PRBT/PRMT

Display the user change permission or inhibition status of the log-in function.

KEY LINK FUNCTION

On/Off

Displays the ON/OFF status of the Intelligent Key interlock function.

KEY NUMBER

KEY 1/KEY 2/KEY 3/KEY 4

NOTE: This item is displayed, but cannot be monitored

KEY 1

NO REG/ACT/INACT

NOTE: This item is displayed, but cannot be monitored

KEY 2

NO REG/ACT/INACT

NOTE: This item is displayed, but cannot be monitored

KEY 3

NO REG/ACT/INACT

NOTE: This item is displayed, but cannot be monitored

KEY 4

NO REG/ACT/INACT

NOTE: This item is displayed, but cannot be monitored

Log-in user setting 1*

Off/User1/User2/User3/User4

The user number that is used for transmitting the settings of the log-in function is displayed.

Log-in user setting 2*

Off/User1/User2/User3/User4

The user number that is used for receiving the settings of the log-in function is displayed.

Log-in user setting copy status*

On/Off

The copy status of the Log-in function is displayed with "On/Off".

Forward SW

On/Off

ON (folded down)/OFF (other than folded down) status judged from the folded up/folded down condition signal.

Walk in SW

On/Off

ON (pressed)/OFF (other than pressed) status judged from the power walk-in switch operation signal.

Forward limit SW

On/Off

ON (front edge)/OFF (other than front edge) status judged from the front end position signal.

Seat belt buckle SW

On/Off

ON (fastened)/OFF (other than fastened) status judged from the seat belt fastening/releasing condition signal.

*: For models without automatic drive positioner system, this item is not used.