FixVault

DTC Detection Logic

DTC CONSULT Screen Terms DTC Detecting Condition
(Trouble Diagnosis Content) [Malfunction Type]
P0140 13 O2 SENSOR B1 SENSOR 2
(O2 sensor circuit no activity detected bank 1 sensor 2)
CIRCUIT OPEN Diagnosis condition -
Signal (terminal) -
Threshold The signal of oxygen sensor (cylinder bank 1) does not change. There is an open circuit.