FixVault

DTC Detection Logic

DTC No. CONSULT screen terms DTC detecting condition
(Trouble diagnosis content) Malfunction type
P0011 64 CAMSHAFT A POSITION
("A" Camshaft position - timing over-advanced or system performance bank 1)
SIGNAL PLAUSIBILITY ERROR The position of the intake camshaft (cylinder bank 1) deviates from the specified value. There is an implausible signal.
77 COMMAND POSI NOT REACHABLE The position of the intake camshaft (cylinder bank 1) deviates from the specified value. The commanded position cannot be reached.