FixVault

Diagnosis Procedure

  1. PERFORM INITIALIZATION PROCEDURE

    Initialization procedure is executed and operation is confirmed.

    Refer to DESCRIPTION .

    Is the inspection result normal?

    YES 

    INSPECTION END

    NO 

    GO TO STEP 2  .

  2. CHECK DRIVER SIDE DOOR LOCK ASSEMBLY (DOOR KEY CYLINDER SWITCH)

    Check driver side door lock assembly (door key cylinder switch).

    Refer to COMPONENT FUNCTION CHECK .

    Is the inspection result normal?

    YES 

    GO TO STEP 3  .

    NO 

    Repair or replace the malfunctioning parts.

  3. CONFIRM THE OPERATION

    Confirm the operation again.

    Is the result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    GO TO STEP 1  .