FixVault

DTC Detection Logic

DTC No. Trouble diagnosis
(Trouble diagnosis content)
Detecting condition Possible cause
P0520 EOP sensor circuit Signal voltage from the EOP sensor remains at more than 4.9 V / less than 0.26 V for 5 seconds or more.
  • Harness or connectors

    (EOP sensor circuit is open or shorted.)

  • Engine oil level abnormality
  • EOP sensor
  • Power steering pressure sensor
  • FRP sensor
  • Sensor power suplly 3