DTC Diagnosis Procedure
- CHECK DTC PRIORITY
If DTC P2565 is displayed with DTC P0643, first perform the confirmation procedure (trouble diagnosis) for DTC P0643.
Is applicable DTC detected?
YES
Perform diagnosis for P0643. Refer to DTC Description .
NO
GO TO 2.
- CHECK WASTEGATE CONTROL VALVE POSITION SENSOR POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect electric wastegate control actuator (bank 1) harness connector.
- Turn ignition switch ON.
- Check the voltage between electric wastegate control actuator (bank 1) harness connector and ground.
+
-
Voltage
(Approx.)
Electric wastegate control actuator (bank 1)
Connector
Terminal
F139
3
Ground
5 V
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 3.
- CHECK WASTEGATE CONTROL VALVE POSITION SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between electric wastegate control actuator (bank 1) harness connector and ECM harness connector.
Electric wastegate control actuator (bank 1)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F139
3
F142
130
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
Perform the trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure .
NO
Repair or replace error-detected parts.
- CHECK WASTEGATE CONTROL VALVE POSITION SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between electric wastegate control actuator (bank 1) harness connector and ECM harness connector.
Electric wastegate control actuator (bank 1)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F139
2
F142
99
Existed
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace error-detected parts.
- CHECK WASTEGATE CONTROL VALVE POSITION SENSOR INPUT SIGNAL CIRCUIT
- Check the continuity between electric wastegate control actuator (bank 1) harness connector and ECM harness connector.
Electric wastegate control actuator (bank 1)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F139
1
F142
118
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace error-detected parts.
- Check the continuity between electric wastegate control actuator (bank 1) harness connector and ECM harness connector.
- CHECK ELECTRIC WASTEGATE CONTROL ACTUATOR (BANK 1)
Check the electric wastegate control actuator (bank 1). Refer to Component Inspection .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace turbocharger assembly [do not replace electric wastegate control actuator (bank 1) only]. Refer to TURBOCHARGER : Removal & Installation .