Work Procedure
Perform the following procedures after replacing the around view monitor control unit:
- REPLACE AROUND VIEW MONITOR CONTROL UNIT
Replace around view monitor control unit. Refer to Removal and Installation .
GO TO 2.
- WRITING MAC KEY
Perform MAC key writing. Refer to Description .
GO TO 3.
- PERFORM CONFIGURATION CAUTION: Always write the MAC key before writing the around view monitor control unit configuration.
Perform configuration. Refer to Description .
GO TO 4.
- WRITING OF CALIBRATION DATA
Write the calibration data stored in the camera. Refer to Work Procedure .
GO TO 5.
- PERFORM SELF-DIAGNOSIS
CONSULT
- Select "Self Diagnostic Result" mode of "AVM".
- Check if any DTCs are detected.
Are any DTCs detected?
YES
Perform the trouble diagnosis for the detected DTC. Refer to DTC Index .
NO
GO TO 6.
- OPERATION CHECK
Confirm that the operation of the intelligent around view monitor and the camera image (reference line, expected route) are normal.
Work End.