FixVault

Component Inspection

  1. CHECK COOLING FAN SPEED SENSOR 
    1. Turn ignition switch OFF.
    2. Disconnect electrically-controlled cooling fan coupling harness connector.
    3. Rotate the electrically-controlled cooling fan coupling slowly with hand and check the voltage between electrically-controlled cooling fan coupling connector terminals under the following conditions.

      +

      -

      Condition

      Voltage (V)

      (Approx.)

      Electrically-controlled cooling fan coupling

      Terminal

      5

      4

      • 5 V direct current supply to terminal 2
      • Terminal 4 connect to ground

      0 <=> 5

      NOTE: The voltage is in waveform

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Replace Electrically-controlled cooling fan coupling.