FixVault

Test 9 - Detonation Sensor (Code 66)

  1. Unplug ECU connectors at ECU, and at knock sensor. Check resistance across sensor. Resistance should be 650-800 ohms. Replace sensor if reading is different.
  2. If reading is okay, check continuity of circuit as indicated in table. If readings are incorrect, repair or replace harness.
TESTING KNOCK SENSOR CIRCUIT

Wire Color ECU Connector Terminal No. Resistance (Ohms)
White 37 0
White Ground Infinity
Black 28 0