FixVault

Adjustment Specifications

CARBURETOR ADJUSTMENT SPECIFICATIONS

Application Specification
Float Level (1)
Float Drop 0.059 (1.50)
Choke Linkage (2) 0.050-0.059 (1.28-1.50)
Secondary Throttle 0.240-0.300 (6.10-7.60)
Unloader Setting n/a
Vacuum Break n/a
(1) Float parallel with top of float bowl. See adjustment procedure.
(2) Man. Trans. For Auto. Trans., clearance should be 0.059-0.069" (1.51-1.7 mm).