Float Drop
With the sight glass cover removed and carburetor inverted, gently lift up float and measure clearance between needle valve and float seat. Clearance should be .059" (1.50 mm). Adjust by bending float stop. See Fig 1 .
With the sight glass cover removed and carburetor inverted, gently lift up float and measure clearance between needle valve and float seat. Clearance should be .059" (1.50 mm). Adjust by bending float stop. See Fig 1 .