FixVault

Hydraulic Pressure Test: Notes

NOTE: Hydraulic pressure test should be performed with transmission fluid temperature of 122-176°F (50-80°C). DO NOT  maintain RPM for more than 5 seconds. Allow one minute interval between tests.