FixVault

Manifold Air Temperature (Mat) Sensor Test (Impulse)

  1. Remove MAT sensor from intake manifold. The MAT sensor is located near throttle position sensor and contains a Blue/Black and Black/White wire connector.
  2. Using ohmmeter, check resistance across sensor terminals. Reading should vary with temperature. Replace sensor if not within specification. See MAT SENSOR RESISTANCE SPECIFICATIONS table.
NOTE: If a MAT sensor problem develops, ECM will set a Code 23A or 23B. For additional testing procedures, see appropriate test procedure in TESTS W/CODES article.
MAT SENSOR RESISTANCE SPECIFICATIONS

Temperature °F (°C) Ohms
-40 (-40) 100,700
0 (-18) 25,000
19 (-7) 13,500
39 (4) 7500
68 (20) 3400
100 (38) 1800
158 (70) 450
212 (100) 185
CAUTION: DO NOT attempt to measure O2 sensor output voltage with a conventional voltmeter. Current drain of voltmeter could damage sensor. Oxygen sensor voltage signal can be measured using a 10-megohm (minimum input impedance) digital voltmeter.