Boost Gauge
- Disconnect battery negative cable. Remove instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Using ohmmeter, measure resistance between IGN and boost sensor terminals. SeeFig 1 .
- Resistance should be approximately 62.6 ohms. Measure resistance between IGN and GND terminals. SeeFig 1 . Resistance should be approximately 112.8 ohms. If resistance readings are not as specified, replace boost gauge.