Solenoid Return Test
- Connect negative battery lead to terminal 50 (terminal "C" on 3.2L) and ground. See Fig 1 or Fig 2 . Connect battery positive lead to terminal "C" (terminal "M" on 3.2L). Pinion should flutter.
- Disconnect lead at terminal 50 (terminal "C" on 3.2L). Pinion should immediately return to stationary position. If pinion does not return to stationary position, replace solenoid.