FixVault

Power Mirror Motor

Disconnect mirror electrical connector. Test power mirror motor by applying battery voltage to appropriate mirror terminal and ground appropriate terminal. See the POWER MIRROR MOTOR TEST  . SeeFig 1 . If power mirror does not operate in all positions, replace appropriate mirror.

POWER MIRROR MOTOR TEST (1)

Apply 12 Volts To Term. No. Ground Term. No. Mirror Operation
1 3 UP
3 1 DOWN
2 3 LEFT
3 2 RIGHT
(1) SeeFig 1 for terminal locations.
Fig 1: Power Mirror Motor Terminal ID
G93H83466Courtesy of ISUZU MOTOR CO.