FixVault

Component Testing: Voltmeter: 2.6L

  1. Remove instrument cluster leaving wires connected. Refer to INSTRUMENT CLUSTER  under REMOVAL & INSTALLATION. Using a DVOM, measure voltage at vehicle voltmeter terminals. SeeFigure .
  2. With ignition switch in ON position, compare readings on both voltmeters. Voltage difference between voltmeters should be less than .5 volt. Replace gauge if reading is not as specified.