Bench Testing: Rotor
- Measure diameter of slip rings. If less than 1.02" (26 mm) replace rotor. If slip ring diameter is within specification, go to next step.
- Using an ohmmeter, check rotor coil resistance across slip rings. If ohmmeter reading is greater than 3.75 ohms at 68°F (20°C), rotor is defective.
- If ohmmeter reading is 3.75 ohms or less at 68°F (20°C), connect an ohmmeter between one slip ring and rotor core. If continuity exists, replace rotor assembly.