FixVault

Modulator Unit: Removal

Relieve accumulator/line pressure. See RELIEVING ACCUMULATOR/LINE PRESSURE under BLEEDING BRAKE SYSTEM. Disconnect 14-pin modulator unit connector and 2-pin pump motor connector. Remove wiring harness clip from modulator bracket. Mark brakelines for reassembly and disconnect all brakelines. Remove 3, 8-mm nuts. Remove modulator unit from bracket. See Figure .