FixVault

Cylinder Block

CYLINDER BLOCK

Application In. (mm)
Cylinder Bore
DOHC
No Letter, "A" Or "I" Block (1)
Standard Diameter 3.4256-3.4260 (87.010-87.020)
Service Limit 3.4279 (87.070)
"B" Or "II" Block (1)
Standard Diameter 3.4252-3.4256 (87.000-87.010)
Service Limit 3.4279 (87.070)
Reboring Limit 0.010 (0.25)
Maximum Taper 0.002 (0.05)
1997 SOHC
No Letter, "A" Or "I" Block (1)
Standard Diameter 3.3469-3.3472 (85.010-85.020)
Service Limit 3.3492 (85.070)
"B" Or "II" Block (1)
Standard Diameter 3.3465-3.3469 (85.000-85.010)
Service Limit 3.3492 (85.070)
Reboring Limit 0.02 (0.5)
Maximum Taper 0.002 (0.05)
Maximum Deck Surface Warpage
Standard 0.003 (0.08)
Service Limit 0.004 (0.10)
1998 SOHC
No Letter, "A" Or "I" Block (1)
Standard Diameter 3.3863-3.3866 (86.010-86.020)
Service Limit 3.3886 (85.970)
"B" Or "II" Block (1)
Standard Diameter 3.3858-3.3862 (86.000-86.010)
Service Limit 3.3886 (86.070)
Reboring Limit 0.02 (0.5)
Maximum Taper 0.002 (0.05)
Maximum Deck Surface Warpage
Standard 0.003 (0.08)
Service Limit 0.004 (0.10)
(1) Letters or bars have been stamped on end of cylinder block above water pump.