FixVault

Circuit Description

To provide best possible combination of driveability, fuel economy and emission control, a closed loop air/fuel metering system is used. When the vehicle is first started, PCM controls fuel delivery in open loop, ignoring H02S signals and calculates air/fuel mixture ratio based on inputs from the ECT, TPS, and MAF sensors. PCM will begin using Bank 1 HO2S No. 1 and Bank 2 HO2S No. 1 signals to control fuel delivery under closed loop conditions when following have been met: