FixVault

D8: Check For O2 Sensor Continuity

  1. With EM012 and EM022 disconnected, measure the resistance between EM012/017 and EM022/002
    Fig 1: Measuring Resistance Between EM012/017 And EM022/002
    G04355485Courtesy of JAGUAR CARS, INC.
    • Is the resistance < 0.5OHM 

    Yes  : GO to D9 

    No  : Inspect connectors EM012, and EM022 for corrosion, damaged / pushed back pins or repair the harness; reconnect plug(s)

    GO to D11