Actuator Fault Codes
NOTE:
* The water valve operates on a 6 second pulse, ie 3 seconds ON, 3 seconds OFF.
| Outlet | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Code | Blower Level | Centre vent | Foot | Defrost | Cool air bypass | Fresh / Recirc. | Compressor | Water valve | Water pump |
| 20 | 0 | open | closed | closed | closed | fresh | OFF | closed | OFF |
| 21 | 1 | open | closed | closed | closed | fresh | OFF | closed | ON |
| 22 | 10 | open | closed | closed | open | half open | A/C ON | closed | ON |
| 23 | 17 | bleed | half open | closed | half open | half open | A/C ON | 6s pulse * | ON |
| 24 | 17 | bleed | half open | closed | closed | recirc. | A/C ON | 6s pulse * | ON |
| 25 | 23 | closed | open | bleed | closed | recirc. | A/C ON | open | ON |
| 26 | 23 | closed | half open | half open | closed | recirc. | A/C ON | open | ON |
| 27 | 31 | closed | closed | open | closed | open | A/C ON | open | ON |