Remote Function Actuator Module Will Not Respond To Diagnostic Equipment Requests (SSM74060)
Publication date: 2018-09-05Reference number: SSM74060
REMOTE FUNCTION ACTUATOR MODULE WILL NOT RESPOND TO DIAGNOSTIC EQUIPMENT REQUESTS
TECHNICAL SERVICE BULLETIN
| JAGUAR: | F-PACE/X761; F-TYPE/X152; XE/X760; XF/X260; XJ/X351 |
| SERVICE CATEGORY: | Electrical |
ISSUE
Following what appears to be a successful software update to the Remote Function Actuator (RFA) or replacement module using Pathfinder or Symptom Driven Diagnostics (SDD) the module appears to be unresponsive to any further diagnostic commands or smart key remote operation.
CAUSE
Diagnostics Layer (DSL) lock up causes a continuous loop between the Transport Layer (TPL) and DSL.
ACTION
If the concern appears during a RFA module replacement/software update, carry out a battery hard reset by disconnecting the battery earth lead for approximately 30 seconds and re-connect the earth lead. If the smart key remote operation is not restored continue with diagnostics using Pathfinder/SDD and with reference to TOPIx.
Technicians - Please rate this SSM and provide comments so that future communications can be improved.
1 = Poor - Basic information provided - The SSM does not help me resolve the customer concern.
3 = Average - Adequate information provided - The SSM partially helps me resolve the customer concern.
5 = Excellent - All required information provided to resolve the customer concern.