Float Level
Remove air horn and float assembly from carburetor, remove air horn gasket and invert assembly so that weight of float is on seated intake needle. Use gauge of correct size (see Specifications ) to measure distance from gasket seat on air horn to top of float at free end (see Fig 1).
CAUTION:
Weight of float only should be on in-take needle (excessive pressure will compress spring-loaded needle and cause false setting).
If distance not correct, adjust by bending float arm.
NOTE:
Do not bend tab at end of float arm. This dry float setting is only float adjustment required.