Test 3A - Repairing Security Light Flashing Constantly
NOTE:
For connector terminal identification, refer to CONNECTOR IDENTIFICATION
. For appropriate wiring diagram, see appropriate chassis wiring diagram in the WIRING DIAGRAMS
article.
- Disconnect VTA module. See Figure in TEST 2A. Using DRB-II, check voltage at arm sense terminal No. 6 (Pink/Orange wire) of VTA module connector. If voltage is less than one volt, replace VTA module. Perform TEST VER-1 . If voltage is more than one volt, disconnect remote keyless entry module. See Fig 1 .
- Using DRB-II, check voltage at arm sense circuit terminal No. 6 (Pink/Orange wire). If voltage is more than one volt, repair shorted arm sense (Pink/Orange wire). Perform TEST VER-1 . If voltage is less than one volt, replace remote keyless entry module. Perform TEST VER-1 .