Test 7E - Short To Battery

NOTE: For connector terminal identification, see CONNECTOR IDENTIFICATION  . For wiring diagram, see WIRING DIAGRAMS article in this section.
  1. Using DRB in ohmmeter mode, check instrument cluster connector ground circuit (Black/Light Green wire).
  2. If resistance is more than 5 ohms, repair open circuit in Black/Light Green wire. Perform TEST VER-1  . If resistance is less than 5 ohms, replace instrument cluster. Perform TEST VER-1  .