Test 52A - Inoperative Warning Lamp
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION in this article. For appropriate wiring diagram, see WIRING DIAGRAMS section at the end of this article. Perform TEST VER-1B after each repair.
CAUTION:
Always turn ignition off prior to disconnecting or connecting any module connector.
- Turn ignition off. Disconnect MIC connector. Check connector, and clean or repair connector as necessary. If connector is okay, go to next step.
- Remove and inspect inoperative warning lamp. If lamp is open, replace lamp. If lamp is okay, replace MIC printed circuit board.