FixVault

Test 52A - Inoperative Warning Lamp

NOTE: For connector terminal identification, see CONNECTOR IDENTIFICATION  in this article. For appropriate wiring diagram, see WIRING DIAGRAMS  section at the end of this article. Perform TEST VER-1B  after each repair.
CAUTION: Always turn ignition off prior to disconnecting or connecting any module connector.
  1. Turn ignition off. Disconnect MIC connector. Check connector, and clean or repair connector as necessary. If connector is okay, go to next step.
  2. Remove and inspect inoperative warning lamp. If lamp is open, replace lamp. If lamp is okay, replace MIC printed circuit board.