Turn Signal Indicator Light Test
- Disconnect negative battery cable. Remove instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Connect negative battery cable. Actuate hazard warning switch.
- Check for battery voltage at instrument cluster connector C2 terminal No. 6 (Tan wire) and connector C1 terminal No. 10 (Light Green/White wire). There should be a switching battery voltage signal. If battery voltage does not exist, repair open circuit between turn signal switch and instrument cluster. If battery voltage exists, replace faulty bulb(s).