Power Liftgate System: Hinge: Installation
NOTE:
It is not necessary to remove the liftgate to replace one or both hinges. The hinges can be replaced one at a time.
NOTE:
Use a suitable body sealer on the hinge to body mating surfaces prior to installation.
- Position the hinge on the roof panel and on the liftgate.
- Install and tighten hinge screws at roof panel to 28 N.m (21 ft. lbs.).
- Install hinge screws at liftgate and tighten to 28 N.m (21 ft. lbs.).
- Install the upper liftgate opening trim panel. Refer to INSTALLATION .
- Check the liftgate for proper alignment and operation. (Refer to ADJUSTMENTS .
- Check for water leaks at hinge to body screws.