FixVault

Removal - Front

  1. Remove the waterdam. See WATERDAM  .
  2. Raise the glass. Using a long flat blade or hook type tool, disengage clips attaching glass retainer to regulator lift plate.
  3. Disconnect the glass from the regulator lift plate and re-install the clips.
  4. Secure the glass in the up position using a wood wedge, tape or equivalent.
  5. Loosen the bolts.
  6. Disconnect the runout tube clip.
  7. Disconnect the electrical connector and remove the regulator.