HCU (Hydraulic Control Unit): Installation
| 1 - BRAKE LINES |
| 2 - ABM UNIT |
| 3 - MOUNTING NUTS |
NOTE:
If the ABM module is being replaced with a new ABM module it must be reprogrammed with the use of a scan tool.
- Install ABM (2) on the mounting studs (3). See Fig 1.
- Install mounting nuts. Tighten to 14.1 N.m (125 in. lbs.). See Fig 1.
- Install brake lines (1) to the ABM (2) and tighten to 20 N.m (180 in. lbs.). See Fig 1.
1 - ABM MODULE 2 - ABM MODULE MOUNTING SCREWS 3 - ABM UNIT 4 - ELECTRICAL CONNECTOR 5 - MOUNTING BRACKET - Install wiring harness connector (4) to the ABM (3) and push down on the release to secure the connector. See Fig 2
- Install negative battery cable to the battery.
- Bleed ABS brake system (Refer to STANDARD PROCEDURE - ABS BRAKE BLEEDING) .