FixVault

Alternative Procedure

Fig 1: Removal Of Module
GC0084313Courtesy of CHRYSLER GROUP, LLC
NOTE:

If the electric fuel pump is not operating, the fuel tank must be removed and drained through the fuel pump module opening of the fuel tank.

  1. Disconnect and isolate the negative battery cable.
  2. Raise and support the vehicle. Refer to HOISTING, STANDARD PROCEDURE .
  3. Remove the fuel tank. Refer to TANK, FUEL, REMOVAL  or TANK, FUEL, REMOVAL .
  4. Remove the fuel pump module. Refer to MODULE, FUEL PUMP, REMOVAL  or MODULE, FUEL PUMP, REMOVAL .
  5. Position a 3/8" hose into the fuel pump module opening of the fuel tank.
  6. Attach the opposite end of this hose to an OSHA approved fuel storage tank such as the JohnDow Gas Caddy 320-FC-P30-A or equivalent.
  7. Using the gas caddy, evacuate the fuel tank.