FixVault

Set Condition

Condition one:  Input speed RPM is less than 150 RPM with a Output speed RPM greater than 1000 RPM for the period of 5 seconds.

Condition two:  Input speed RPM last value is greater than 1000 RPM where as the Input speed RPM current value is zero RPM for the period of 500 msec.

Condition three:  Both the Input and Output Speed sensors are less than 150 RPM with a actual vehicle speed greater than 10 Km/h. (Note: this is an indication of either the power supply to both sensors is open or the C106 connector is disconnected.)